Get free Quote

Dual & Multi-Tube Furnace

Brother Furnace dual and multi-tube furnace is designed for parallel material testing, multi-sample heat treatment, atmosphere comparison, catalyst screening, battery material R&D and laboratory process development. Multiple tube channels can be configured with shared or independent temperature control, shared or independent gas lines, and vacuum or controlled atmosphere systems.

  • 2–4+ Tubes
    Dual tube, triple tube, four-tube or custom multi-tube design
  • Parallel Tests
    Process multiple samples or conditions in one furnace system
  • Vacuum / Gas
    Shared or independent atmosphere and vacuum configuration
  • Custom Control
    Shared heating or independent temperature control options
Dual & Multi-Tube Furnace
  • Factory Manufacturer

    Designed, assembled and tested by Brother Furnace engineering team.
  • Parallel Testing

    Multiple tube channels help process several samples or test groups at the same time.
  • Gas Line Options

    Shared or independent gas inlet, exhaust, flowmeter and vacuum line can be configured.
  • Global Support

    Technical selection, installation guidance, remote service and spare parts support.
  • Suitable for parallel testing and comparison experiments
  • Tube quantity and arrangement can be customized
  • Shared or independent heating design available
  • Shared or independent gas/vacuum line options
Product Overview

Multi-Channel Tube Furnace for Parallel Material Research

Brother Furnace dual and multi-tube furnace is developed for universities, research institutes, catalyst laboratories, battery material R&D centers, ceramic research labs and industrial testing facilities that need higher sample throughput and better experiment efficiency.

Compared with a single tube furnace, a dual or multi-tube furnace can process multiple samples in one equipment platform. Depending on the process, the furnace can be designed with shared heating for same-temperature experiments or independent heating modules for different temperature conditions. Each tube can also be equipped with independent gas inlet, outlet, flow control, vacuum valve or exhaust line when different atmosphere comparison is required.

Core Advantages

Why Choose Brother Furnace
Dual & Multi-Tube Furnace

The equipment combines multi-channel sample processing, flexible tube quantity, optional independent gas systems, customizable temperature control and reliable safety protection for advanced laboratory R&D.

  • Parallel Experiment Efficiency

    Process multiple samples or multiple test groups simultaneously to reduce total experiment time.

  • Independent Atmosphere Options

    Each tube can use independent gas flow and exhaust when different atmosphere comparison is required.

  • Space Saving Design

    One multi-tube furnace can replace several single tube furnaces and reduce laboratory space usage.

  • Custom Tube Layout

    Tube quantity, tube diameter, tube material, gas line and heating control mode can be customized.

Tube Quantity Options

Dual Tube, Triple Tube and Custom Multi-Tube Designs

Tube quantity and arrangement should be selected according to sample throughput, experiment type, gas line configuration and available laboratory space.

Dual Tube Furnace

Two-tube layout for paired comparison experiments

  • Suitable for two sample groups
  • Useful for atmosphere comparison
  • Lower cost than multiple single tube furnaces
  • Good for university and R&D laboratories

Triple / Four-Tube Furnace

Higher sample throughput for screening work

  • Suitable for catalyst screening
  • Supports multiple material comparison
  • Helps shorten R&D testing cycles
  • Can be configured with shared or independent gas lines

Custom Multi-Tube Furnace

Customized tube quantity, spacing and layout

  • Tube quantity can be customized
  • Horizontal or stacked layout available
  • Same or mixed tube diameters can be discussed
  • Designed according to process and installation space
Heating & Gas Design

Shared System or Independent Channel Control?

The correct design depends on whether your experiment requires the same temperature and gas condition, or different conditions for each tube channel.

  • Shared Heating Design

    Multiple tubes share one heating environment, suitable for same-temperature parallel processing and lower cost projects.

  • Independent Heating Design

    Each tube can have its own heating and control system when different temperature conditions are required.

  • Shared Gas Line

    All tubes use the same atmosphere, suitable for same-condition multi-sample treatment.

  • Independent Gas Line

    Each tube has separate gas inlet, flow control and exhaust for atmosphere comparison and cross-contamination reduction.

Applications

Dual & Multi-Tube Furnace Applications

This furnace is suitable for laboratories and R&D facilities that require parallel sample processing, comparative atmosphere experiments and efficient material screening.

  • Parallel material sintering
  • Comparative atmosphere experiments
  • Catalyst screening and activation
  • Battery material R&D
  • Ceramic powder heat treatment
  • Semiconductor material testing
  • CVD process comparison
  • Multi-sample annealing
Comparison

Dual & Multi-Tube Furnace vs Single Tube Furnace

A single tube furnace is suitable for routine one-process heating, while a dual or multi-tube furnace improves efficiency when multiple samples or conditions need to be tested.

Comparison Item Dual & Multi-Tube Furnace Single Tube Furnace
Sample Throughput Multiple samples or test groups per run One sample batch per run
Experiment Efficiency Higher for parallel testing and screening Lower when many samples need comparison
Atmosphere Comparison Possible with independent gas lines Usually one gas condition per run
Laboratory Space One machine can replace multiple single tube furnaces Multiple furnaces may be needed
Best For Parallel testing, R&D screening, comparative experiments Routine single-process heating
Vacuum & Atmosphere

Shared or Independent Vacuum and Gas Lines

Dual and multi-tube furnace gas systems can be designed as a shared gas/vacuum system or as independent gas/vacuum lines for each tube, depending on the process and comparison requirements.

  • Shared Vacuum System

    Multiple tubes can share one vacuum pump and manifold when all channels use similar vacuum conditions.

  • Independent Vacuum Lines

    Each tube can be equipped with an independent vacuum valve and line for separate evacuation control.

  • Inert Gas Atmosphere

    Nitrogen, argon or other inert gases can be used for protective atmosphere heat treatment.

  • Independent Flow Control

    Each tube can use its own flowmeter or mass flow controller for atmosphere comparison.

  • Cross-Contamination Control

    Separate gas inlets and exhaust lines help reduce cross-contamination between different process gases.

  • Hydrogen Safety Option

    Hydrogen or flammable gas applications require purging, exhaust protection and safety interlock design.

Control & Safety

Programmable Control and
Safe Multi-Channel Operation

The control system can be designed for shared furnace operation or independent channel management, with optional data recording and safety protection for gas, vacuum and temperature conditions.

  • Programmable Temperature Curves

    Heating, holding and cooling programs can be set according to material process requirements.

  • Independent Channel Control

    Independent temperature control can be configured when each tube needs different temperature conditions.

  • Touch Screen Option

    PLC touch screen, recipe storage, data recording and communication interface can be added.

  • Gas Pressure Monitoring

    Gas pressure protection and vacuum pressure monitoring can be configured according to process needs.

  • Over-Temperature Protection

    Over-temperature alarm and power-off protection improve high-temperature operation safety.

  • Electrical Leakage Protection

    Electrical leakage protection and emergency stop can be configured for safer laboratory operation.

Configuration

Standard Parts and Optional Accessories

Standard configuration covers basic multi-tube furnace operation. Optional accessories can be added for independent control, gas comparison, vacuum operation, data recording and special safety requirements.

Standard Parts

  • Furnace body and heating chamber
  • Furnace tubes according to selected tube quantity
  • Tube plugs and sealing parts
  • Thermocouple and temperature controller
  • Basic flange and vacuum/gas connection
  • Vacuum gauge according to configuration
  • Operation manual and basic technical documents

Optional Accessories

  • Independent temperature control for each tube
  • Independent gas line for each tube
  • Independent vacuum valve and exhaust line
  • Float flowmeter or mass flow controller
  • Vacuum pump or high vacuum system
  • Touch screen and data recording system
  • Customized tube quantity and tube diameter
  • Hydrogen or reducing gas safety package
Technical Parameters

Dual & Multi-Tube Furnace
Typical Specifications

Final technical parameters depend on tube quantity, temperature level, tube diameter, heating zone, heating control mode, gas line mode and vacuum configuration.

Item Typical Options Notes
Tube Quantity 2 tubes / 3 tubes / 4 tubes / custom Selected according to sample throughput and comparison requirements.
Temperature Level 1200°C / 1400°C / 1600°C Selected according to working temperature and tube material.
Tube Material Quartz tube / alumina tube / metal tube Selected according to temperature, atmosphere and material compatibility.
Tube Diameter 40 / 60 / 80 / 100 / 120mm or customized Selected according to sample size and gas flow requirement.
Heating Zone 300mm / 450mm / customized Longer heating zone can be customized for larger samples.
Heating Control Mode Shared heating / independent tube control Independent control is recommended for different temperature comparison.
Gas Line Mode Shared gas line / independent gas line Independent gas line is recommended for different atmosphere comparison.
Vacuum Mode Shared vacuum / independent vacuum valve Selected according to whether each tube needs separate vacuum control.
Control System PID controller / touch screen / data recording Optional PLC, recipe storage and communication interface available.
Power Supply 220V / 380V, single phase / three phase Customized according to destination country and furnace power.
Selection Guide

How to Choose the Right
Multi-Zone Tube Furnace

Model selection should be based on working temperature, number of heating zones, heating zone length, uniform temperature area, gradient requirement, atmosphere, vacuum level and CVD process conditions.

Process Requirement Recommended Zone Design Selection Notes
Basic dual-temperature experiment 2-Zone Tube Furnace Suitable for simple temperature gradient or two-step heating processes.
Long constant temperature zone 3-Zone Tube Furnace Most common option; end zones compensate heat loss and improve central uniformity.
Long tube and complex profile 5-Zone Tube Furnace Recommended for advanced gradient, long heating area and complex CVD processes.
Custom gradient design Customized multi-zone layout Provide desired zone temperatures, heating length and process target before quotation.
Selection Item Available Options Recommendation
Temperature Level 1200°C / 1400°C / 1600°C Select according to continuous working temperature and process atmosphere.
Tube Material Quartz tube / alumina tube Quartz tube for 1200°C series; alumina tube for 1400°C and 1600°C series.
Tube Outer Diameter 40 / 60 / 80 / 100 / 120mm or custom Select according to sample size, boat size and gas flow requirement.
Heating Zone Length 220mm / 300mm per zone or custom Longer heating length is recommended for larger uniform zone or long samples.
Process Condition Recommended Configuration Notes
Basic Vacuum Mechanical pump + vacuum gauge Suitable for standard vacuum heat treatment and research processes.
Protective Atmosphere Nitrogen / argon + flowmeter Recommended for oxidation-sensitive materials.
CVD Process Multi-gas system + mass flow controllers Recommended for deposition, nanotube growth and gas reaction processes.
Hydrogen or Reducing Gas Safety interlock, purging and exhaust protection Special safety design should be confirmed before quotation.
Quotation Checklist

Information Needed Before
Technical Proposal

Please provide the following process details so our engineers can recommend the right tube quantity, heating structure, gas system, vacuum configuration and control system.

01

Tube Quantity

Required number of tubes and arrangement preference.

02

Tube Size

Tube diameter, tube length and heating zone length.

03

Temperature

Maximum temperature and continuous working temperature.

04

Heating Control

Shared heating or independent temperature control for each tube.

05

Gas Line Mode

Shared gas line or independent gas inlet/outlet for each tube.

06

Gas Type

Gas atmosphere required for each tube channel.

07

Vacuum Level

Shared vacuum, independent vacuum valve or high vacuum requirement.

08

Sample Details

Sample size, loading quantity and throughput target.

09

Power Supply

Voltage, phase, frequency and local electrical standard.

10

Destination

Destination country, delivery requirement and installation space.

Ordering Process

From Parallel Process Review to
Delivery Support

Brother Furnace helps customers confirm tube quantity, heating control, gas line design, vacuum system and safety configuration before manufacturing and shipment.

  • Step 01

    Requirement Review

    We review sample throughput, tube quantity, gas conditions, vacuum needs and temperature requirements.

    Technical consultation
  • Step 02

    Configuration Proposal

    A suitable dual tube, triple tube, four-tube or custom multi-tube configuration is recommended.

    Quotation support
  • Step 03

    Manufacturing & Test

    The furnace is assembled, wired, inspected and tested before shipment.

    Factory test
  • Step 04

    Packing & Support

    Export packing, operation documents, remote installation guidance and spare parts support are provided.

    Global delivery
Industries & Research Fields

Where This
Dual & Multi-Tube Furnace Is Used

The furnace is suitable for laboratories, research institutes and industrial facilities that require parallel testing, material screening and multi-atmosphere comparison.

University Laboratories Research Institutes Catalyst Research Battery Materials Ceramic Materials Semiconductor Testing Atmosphere Comparison Parallel Sample Testing Industrial R&D Multi-Sample Heat Treatment
FAQ

Dual & Multi-Tube Furnace FAQs

Here are common questions customers ask before purchasing a dual tube or multi-tube furnace for parallel material testing and atmosphere comparison.

What is a dual tube furnace?

A dual tube furnace is a tube furnace with two furnace tube channels. It allows users to process two sample groups at the same time, compare different conditions or improve laboratory testing efficiency.

What is the difference between a dual tube furnace and a single tube furnace?

A single tube furnace processes one sample batch or atmosphere condition per run. A dual or multi-tube furnace can process multiple samples or conditions in parallel, which is useful for R&D screening and comparative testing.

Can each tube have independent temperature control?

Yes. The furnace can be designed with shared heating for same-temperature processing or independent heating and control for each tube when different temperature conditions are required.

Can each tube use a different gas atmosphere?

Yes. Each tube can be configured with independent gas inlet, flowmeter, mass flow controller and exhaust line for atmosphere comparison experiments.

Can each tube be evacuated separately?

Yes. The vacuum system can be designed as shared vacuum or independent vacuum lines with separate valves, depending on whether each tube requires separate evacuation control.

How many tubes can be customized?

Dual tube, triple tube and four-tube designs are common. More tube channels can be customized according to tube diameter, heating layout, gas line design and installation space.

Can the furnace be used for CVD?

Yes. The furnace can be configured with gas inlet/outlet, flow control, vacuum system and suitable tube material for CVD or gas reaction comparison experiments.

What information is needed for quotation?

Please provide tube quantity, tube diameter, heating zone, maximum temperature, working temperature, whether independent heating is required, gas type for each tube, vacuum requirement, sample size, power supply and destination country.

contact us

Get In Touch With Our Engineering Team

Whether you need a custom vacuum furnace quote, technical consultation, or after-sales support — our team responds within 24 hours. Reach us through any of the channels below, or fill in the enquiry form and we will get back to you promptly.

email
seo@bonaregroup.com
Mon – Sat, 9:00 AM – 6:00 PM (CST)
Phone
+8619949278357
We respond within 24 hours on business days
WhatsApp
+8619949278357
Scan QR or click to chat instantly
Send Us an Enquiry

Fill in the form below and our engineers will respond with a tailored recommendation and quotation.