Designed, assembled and tested by Brother Furnace engineering team.
-
Parallel Testing
Multiple tube channels help process several samples or test groups at the same time. -
Gas Line Options
Shared or independent gas inlet, exhaust, flowmeter and vacuum line can be configured. -
Global Support
Technical selection, installation guidance, remote service and spare parts support.
- Suitable for parallel testing and comparison experiments
- Tube quantity and arrangement can be customized
- Shared or independent heating design available
- Shared or independent gas/vacuum line options
Multi-Channel Tube Furnace for Parallel Material Research
Brother Furnace dual and multi-tube furnace is developed for universities, research institutes, catalyst laboratories, battery material R&D centers, ceramic research labs and industrial testing facilities that need higher sample throughput and better experiment efficiency.
Compared with a single tube furnace, a dual or multi-tube furnace can process multiple samples in one equipment platform. Depending on the process, the furnace can be designed with shared heating for same-temperature experiments or independent heating modules for different temperature conditions. Each tube can also be equipped with independent gas inlet, outlet, flow control, vacuum valve or exhaust line when different atmosphere comparison is required.
Why Choose Brother Furnace
Dual & Multi-Tube Furnace
The equipment combines multi-channel sample processing, flexible tube quantity, optional independent gas systems, customizable temperature control and reliable safety protection for advanced laboratory R&D.
-
Parallel Experiment Efficiency
Process multiple samples or multiple test groups simultaneously to reduce total experiment time.
-
Independent Atmosphere Options
Each tube can use independent gas flow and exhaust when different atmosphere comparison is required.
-
Space Saving Design
One multi-tube furnace can replace several single tube furnaces and reduce laboratory space usage.
-
Custom Tube Layout
Tube quantity, tube diameter, tube material, gas line and heating control mode can be customized.
Dual Tube, Triple Tube and Custom Multi-Tube Designs
Tube quantity and arrangement should be selected according to sample throughput, experiment type, gas line configuration and available laboratory space.
Dual Tube Furnace
Two-tube layout for paired comparison experiments
- Suitable for two sample groups
- Useful for atmosphere comparison
- Lower cost than multiple single tube furnaces
- Good for university and R&D laboratories
Triple / Four-Tube Furnace
Higher sample throughput for screening work
- Suitable for catalyst screening
- Supports multiple material comparison
- Helps shorten R&D testing cycles
- Can be configured with shared or independent gas lines
Custom Multi-Tube Furnace
Customized tube quantity, spacing and layout
- Tube quantity can be customized
- Horizontal or stacked layout available
- Same or mixed tube diameters can be discussed
- Designed according to process and installation space
Shared System or Independent Channel Control?
The correct design depends on whether your experiment requires the same temperature and gas condition, or different conditions for each tube channel.
-
Shared Heating Design
Multiple tubes share one heating environment, suitable for same-temperature parallel processing and lower cost projects.
-
Independent Heating Design
Each tube can have its own heating and control system when different temperature conditions are required.
-
Shared Gas Line
All tubes use the same atmosphere, suitable for same-condition multi-sample treatment.
-
Independent Gas Line
Each tube has separate gas inlet, flow control and exhaust for atmosphere comparison and cross-contamination reduction.
Dual & Multi-Tube Furnace Applications
This furnace is suitable for laboratories and R&D facilities that require parallel sample processing, comparative atmosphere experiments and efficient material screening.
- Parallel material sintering
- Comparative atmosphere experiments
- Catalyst screening and activation
- Battery material R&D
- Ceramic powder heat treatment
- Semiconductor material testing
- CVD process comparison
- Multi-sample annealing
Dual & Multi-Tube Furnace vs Single Tube Furnace
A single tube furnace is suitable for routine one-process heating, while a dual or multi-tube furnace improves efficiency when multiple samples or conditions need to be tested.
| Comparison Item | Dual & Multi-Tube Furnace | Single Tube Furnace |
|---|---|---|
| Sample Throughput | Multiple samples or test groups per run | One sample batch per run |
| Experiment Efficiency | Higher for parallel testing and screening | Lower when many samples need comparison |
| Atmosphere Comparison | Possible with independent gas lines | Usually one gas condition per run |
| Laboratory Space | One machine can replace multiple single tube furnaces | Multiple furnaces may be needed |
| Best For | Parallel testing, R&D screening, comparative experiments | Routine single-process heating |
Shared or Independent Vacuum and Gas Lines
Dual and multi-tube furnace gas systems can be designed as a shared gas/vacuum system or as independent gas/vacuum lines for each tube, depending on the process and comparison requirements.
-
Shared Vacuum System
Multiple tubes can share one vacuum pump and manifold when all channels use similar vacuum conditions.
-
Independent Vacuum Lines
Each tube can be equipped with an independent vacuum valve and line for separate evacuation control.
-
Inert Gas Atmosphere
Nitrogen, argon or other inert gases can be used for protective atmosphere heat treatment.
-
Independent Flow Control
Each tube can use its own flowmeter or mass flow controller for atmosphere comparison.
-
Cross-Contamination Control
Separate gas inlets and exhaust lines help reduce cross-contamination between different process gases.
-
Hydrogen Safety Option
Hydrogen or flammable gas applications require purging, exhaust protection and safety interlock design.
Programmable Control and
Safe Multi-Channel Operation
The control system can be designed for shared furnace operation or independent channel management, with optional data recording and safety protection for gas, vacuum and temperature conditions.
-
Programmable Temperature Curves
Heating, holding and cooling programs can be set according to material process requirements.
-
Independent Channel Control
Independent temperature control can be configured when each tube needs different temperature conditions.
-
Touch Screen Option
PLC touch screen, recipe storage, data recording and communication interface can be added.
-
Gas Pressure Monitoring
Gas pressure protection and vacuum pressure monitoring can be configured according to process needs.
-
Over-Temperature Protection
Over-temperature alarm and power-off protection improve high-temperature operation safety.
-
Electrical Leakage Protection
Electrical leakage protection and emergency stop can be configured for safer laboratory operation.
Standard Parts and Optional Accessories
Standard configuration covers basic multi-tube furnace operation. Optional accessories can be added for independent control, gas comparison, vacuum operation, data recording and special safety requirements.
Standard Parts
- Furnace body and heating chamber
- Furnace tubes according to selected tube quantity
- Tube plugs and sealing parts
- Thermocouple and temperature controller
- Basic flange and vacuum/gas connection
- Vacuum gauge according to configuration
- Operation manual and basic technical documents
Optional Accessories
- Independent temperature control for each tube
- Independent gas line for each tube
- Independent vacuum valve and exhaust line
- Float flowmeter or mass flow controller
- Vacuum pump or high vacuum system
- Touch screen and data recording system
- Customized tube quantity and tube diameter
- Hydrogen or reducing gas safety package
Dual & Multi-Tube Furnace
Typical Specifications
Final technical parameters depend on tube quantity, temperature level, tube diameter, heating zone, heating control mode, gas line mode and vacuum configuration.
| Item | Typical Options | Notes |
|---|---|---|
| Tube Quantity | 2 tubes / 3 tubes / 4 tubes / custom | Selected according to sample throughput and comparison requirements. |
| Temperature Level | 1200°C / 1400°C / 1600°C | Selected according to working temperature and tube material. |
| Tube Material | Quartz tube / alumina tube / metal tube | Selected according to temperature, atmosphere and material compatibility. |
| Tube Diameter | 40 / 60 / 80 / 100 / 120mm or customized | Selected according to sample size and gas flow requirement. |
| Heating Zone | 300mm / 450mm / customized | Longer heating zone can be customized for larger samples. |
| Heating Control Mode | Shared heating / independent tube control | Independent control is recommended for different temperature comparison. |
| Gas Line Mode | Shared gas line / independent gas line | Independent gas line is recommended for different atmosphere comparison. |
| Vacuum Mode | Shared vacuum / independent vacuum valve | Selected according to whether each tube needs separate vacuum control. |
| Control System | PID controller / touch screen / data recording | Optional PLC, recipe storage and communication interface available. |
| Power Supply | 220V / 380V, single phase / three phase | Customized according to destination country and furnace power. |
How to Choose the Right
Multi-Zone Tube Furnace
Model selection should be based on working temperature, number of heating zones, heating zone length, uniform temperature area, gradient requirement, atmosphere, vacuum level and CVD process conditions.
| Process Requirement | Recommended Zone Design | Selection Notes |
|---|---|---|
| Basic dual-temperature experiment | 2-Zone Tube Furnace | Suitable for simple temperature gradient or two-step heating processes. |
| Long constant temperature zone | 3-Zone Tube Furnace | Most common option; end zones compensate heat loss and improve central uniformity. |
| Long tube and complex profile | 5-Zone Tube Furnace | Recommended for advanced gradient, long heating area and complex CVD processes. |
| Custom gradient design | Customized multi-zone layout | Provide desired zone temperatures, heating length and process target before quotation. |
| Selection Item | Available Options | Recommendation |
|---|---|---|
| Temperature Level | 1200°C / 1400°C / 1600°C | Select according to continuous working temperature and process atmosphere. |
| Tube Material | Quartz tube / alumina tube | Quartz tube for 1200°C series; alumina tube for 1400°C and 1600°C series. |
| Tube Outer Diameter | 40 / 60 / 80 / 100 / 120mm or custom | Select according to sample size, boat size and gas flow requirement. |
| Heating Zone Length | 220mm / 300mm per zone or custom | Longer heating length is recommended for larger uniform zone or long samples. |
| Process Condition | Recommended Configuration | Notes |
|---|---|---|
| Basic Vacuum | Mechanical pump + vacuum gauge | Suitable for standard vacuum heat treatment and research processes. |
| Protective Atmosphere | Nitrogen / argon + flowmeter | Recommended for oxidation-sensitive materials. |
| CVD Process | Multi-gas system + mass flow controllers | Recommended for deposition, nanotube growth and gas reaction processes. |
| Hydrogen or Reducing Gas | Safety interlock, purging and exhaust protection | Special safety design should be confirmed before quotation. |
Information Needed Before
Technical Proposal
Please provide the following process details so our engineers can recommend the right tube quantity, heating structure, gas system, vacuum configuration and control system.
Tube Quantity
Required number of tubes and arrangement preference.
Tube Size
Tube diameter, tube length and heating zone length.
Temperature
Maximum temperature and continuous working temperature.
Heating Control
Shared heating or independent temperature control for each tube.
Gas Line Mode
Shared gas line or independent gas inlet/outlet for each tube.
Gas Type
Gas atmosphere required for each tube channel.
Vacuum Level
Shared vacuum, independent vacuum valve or high vacuum requirement.
Sample Details
Sample size, loading quantity and throughput target.
Power Supply
Voltage, phase, frequency and local electrical standard.
Destination
Destination country, delivery requirement and installation space.
From Parallel Process Review to
Delivery Support
Brother Furnace helps customers confirm tube quantity, heating control, gas line design, vacuum system and safety configuration before manufacturing and shipment.
-
Step 01
Requirement Review
We review sample throughput, tube quantity, gas conditions, vacuum needs and temperature requirements.
-
Step 02
Configuration Proposal
A suitable dual tube, triple tube, four-tube or custom multi-tube configuration is recommended.
-
Step 03
Manufacturing & Test
The furnace is assembled, wired, inspected and tested before shipment.
-
Step 04
Packing & Support
Export packing, operation documents, remote installation guidance and spare parts support are provided.
Where This
Dual & Multi-Tube Furnace Is Used
The furnace is suitable for laboratories, research institutes and industrial facilities that require parallel testing, material screening and multi-atmosphere comparison.
Dual & Multi-Tube Furnace FAQs
Here are common questions customers ask before purchasing a dual tube or multi-tube furnace for parallel material testing and atmosphere comparison.
What is a dual tube furnace?
A dual tube furnace is a tube furnace with two furnace tube channels. It allows users to process two sample groups at the same time, compare different conditions or improve laboratory testing efficiency.
What is the difference between a dual tube furnace and a single tube furnace?
A single tube furnace processes one sample batch or atmosphere condition per run. A dual or multi-tube furnace can process multiple samples or conditions in parallel, which is useful for R&D screening and comparative testing.
Can each tube have independent temperature control?
Yes. The furnace can be designed with shared heating for same-temperature processing or independent heating and control for each tube when different temperature conditions are required.
Can each tube use a different gas atmosphere?
Yes. Each tube can be configured with independent gas inlet, flowmeter, mass flow controller and exhaust line for atmosphere comparison experiments.
Can each tube be evacuated separately?
Yes. The vacuum system can be designed as shared vacuum or independent vacuum lines with separate valves, depending on whether each tube requires separate evacuation control.
How many tubes can be customized?
Dual tube, triple tube and four-tube designs are common. More tube channels can be customized according to tube diameter, heating layout, gas line design and installation space.
Can the furnace be used for CVD?
Yes. The furnace can be configured with gas inlet/outlet, flow control, vacuum system and suitable tube material for CVD or gas reaction comparison experiments.
What information is needed for quotation?
Please provide tube quantity, tube diameter, heating zone, maximum temperature, working temperature, whether independent heating is required, gas type for each tube, vacuum requirement, sample size, power supply and destination country.